Outback-power-systems VFX Series Programming Manual Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 59
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
21
LED Color LED Action LED Indicates
Green Solid GREEN Inverter ON
Flashing GREEN Search Mode/Slave Power
Off Inverter OFF
Yellow Solid YELLOW AC Source is Connecteced
Flashing YELLOW AC Input Live-Waiting to
Connect to the FX
Off No AC Input Present
Red Solid RED Error-Error Message,
displays on the MATE
Flashing RED Warning: Non-critical FX
fault, the MATE can access
this information
AC Breakers O DC Breakers On
2. With the FXs connected to the HUB, turn only the DC breakers ON and power up the components.
All AC breakers should be OFF.
NOTE: For 3-phase stacking, the jumper in the HUB must be set to the 3ph position.
See the HUB Communications Manager User Guide for further information.
NOTE: Powering up the FXs can cause the red
ERROR STATUS light to blink. After 5-10 seconds,
the green INVERTER light should be bright and
the ERROR and AC IN lights dark. The FX is now
producing AC output voltage.